Products

Industrial Centrifugal Fan
Tunnel Fan & Metro Fan
(Gas Heating) Make-up Air Unit
Infrared Radiant Heaters
Mixed Flow Fan
Axial Flow Fan
Inducing Fan
Kitchen Fume Extractor Fan
Cabinet Fans
Inline Centrifugal Fan
Roof Fan
Wall Mounted Fan
AHU FAN
INFINAIR motors
OEM Customization
Intelligent Control

Products

Wall Mounted Supply/Exhaust Fan-YFWMF

● Wheel Specification: 630~1,800
● Installation: wall mounted
● Volume range: 1,300~174,300 m³/h
● Static pressure range: 0~600 Pa
 
● FLY-YOUNG series patented propeller-type axial wheel,large volume and low noise.
● Variable angle vane make selection more accurate.
● Square housing and easier to install in the wall.
● Balance quality grade up to G2.5 (AMCA 204).
● Standard equipped with bird screen and safety guard.
● Direct drive, high efficient and maintenance-free.
● Elegant appearance matched with the modern architectural design.

Inquiry Online

Air performance design
-- Optimized design of CFD flow field simulation, repeatedly validated.
-- Wheel cutting the air flow asymptotically, air flow direction is stable and high in consistence.
-- 3D curved blade design: Guide air to flow smoothly and reduce turbulent current.

Structure performance design
-- Computer aided design of CAE for optimizing structure performance.
-- The connection technology of hub and blade is highly reliable.
-- Blade end vibration effectively reduced by aided design, prevent blade distortion or breaking after long time running.

Advanced process
-- The 3D curved blades are formed by mould pressing to ensure precision.
-- Special tooling is adopted for hub to ensure precision.
-- Special tooling is adopted for the installation of blade to ensure performance.

High balancing level

-- Balance quality grade up to G2.5(AMCA 204).
-- Keep running safely and steadily for a long time.
-- Extend service life of the fan.

Diverse selection
-- 10 kinds of specifications, the maximum wheel diameter is 1800mm.
-- Wheel material: carbon steel, stainless steel.

Feature

Motor is inside of air stream and lubrication free: suitable for installing on high wall
-- Small size, simple structure, light and stable running.
-- Motor is inside of air stream: effective cooling extended motor life.
-- Lubricating free motor: maintenance free unit suitable for installing on high wall.
-- No belt: no need to climb high to replace belt from time to time.

Square housing: reasonable profile

-- Square opening in concrete, brick or steel wall: easier.
-- Single layer steel wall with horizontal support beam: simple and reliable.

Complete accessories available: thoughtful
-- Standard accessories: 45°weatherhood and stainless steel bird screen (for WEX air exhaust), 90°weatherhood and stainless steel insect screen (for --WSP air supply), safety protective screening and stainless steel fastener.
-- Optional accessories: gravity back-draft damper, casing with epoxy spray coating and explosion resistant structure.
 

Naming

Naming Convention:

Tech Spec

YFWMF Technical Specification

Fan Type

Fan shall be wall mounted exhaust or supply fan with square structure, the drive type shall be belt-drive or direct-drive.

Quality Standards
The fan shall be tested in accordance with AMCA Standard 210 and 300. The manufacturer must own the production license for industrial products and ISO9001 quality system authentication.

Wheel
Wheel shall be propeller-type axial wheel. The blade streamline of the wheel shall be optimized by 3D curved optimal design. Wheel cutting the air flow asymptotically, airflow direction is stable and high in consistence. Blades shall be molded by mold stamping at one time. Use special tooling on installation angle of blade and connection between blade and hub to ensure accuracy, so as to ensure processing quality and high reliability. The wheel shall be statically and dynamically balanced to Level G2.5 as per AMCA204 standard.

Fan Materials
The housing of the fan shall be made of cold rolled panel with epoxy coating [options: colour changes are available] no less than 2mm thickness. The wheel shall be made of steel with epoxy coating to ensure the reliability of the core components and extend the operation life. The material of bent pipe bracket is 20# seamless steel tube, using professional processing equipment to ensure the quality.

Structure
The fan shall be equipped with spin-formed bell mouth. Wheel shall be in precision fit with bell mouth. Guide air to flow smoothly, so as to reduce leakage loss and turbulent current
The fan shall be equipped with firm bent bracket, so as to prevent the fan from generating resonance while running and ensure reliable structure and unique shape
The fan shall be equipped with defend hood in indoor side to ensure personal safety
The fan shall be equipped with defend hood or weather hood in outdoor side to meet the application requirements. And the structure of weather hood shall be meet the requirement of weather proof (Weather hood in outdoor side: Airflow angle is 45 for exhaust type, Airflow angle is 90 for supply type).
Sidewall hanging structure
The fan is made up with indoor defend hood, propeller-type axial wheel, bent pipe bracket, angle iron for installation, outdoor defend hood, motor, belt driven parts (for belt drive type only), and connecting box.
Cabinet structure
The fan is made up with indoor defend hood, cabinet structure for wear wall, propeller-type axial wheel, bent pipe bracket, angle iron for installation, outdoor weather hood, motor, belt driven parts (for belt drive type only), and connecting box.
Direct drive type
The fan wheel shall be directly connected with the motor. The motor shall adopt B5 installation structure, and its protection grade shall be IP54, while insulation class F and temperature rise B. The motor bearing shall be self-lubricating ball bearing.
Junction box of motor: Since the motor is within the fan, the supplier shall provide junction boxes to lead the wire out of the fan, and correct types of junction boxes shall be selected according to the specific applications, such as fire protection type, explosion proof type and common type.
Belt drive type
Shaft: the fan shaft shall be made of 40Cr and hot-treated with homogeneous furnace to ensure that the hardness grade reaches HB286 and the yield limit reaches 550MPa, and anti-corrosion hardening treatment shall be conducted on the surface, and whole dynamic balancing shall be conducted on such surface together with the impeller. The designed operation speed shall at least exceed 25% of the maximum operation speed of the fan.
Belt pulley: the belt pulley shall have specifications as per 150% of the drive power, be made of cast iron, and be fixed with taper lock bush to facilitate dismantlement.
Belt: the belt shall be resistant from oil, heat and electrostatic discharge.
Bearing: independent metal bearing shall be used for supporting the fan shaft to prevent vibration from directly applying onto the motor. The bearing shall be sealed-for-life, self-lubricating ball bearing of pillow block type and metal material. At the maximum rotation speed as indicated in the catalogue, the bearing life shall be no less than (L-10) 80000 hours. And international famous brands shall be selected, such as FYH, and SKF, etc.
Extension lubricating oil tube for bearing: the extended lubricating oil tube is used outside the machine for conveniently filling grease to the bearing without dismantling the fan. And the material of the oil tube shall be copper.
Support: the driving device shall be supported with powder-coated anti-corrosion steel plate, the belt shall be adjustable, and the design of the motor base shall ensure the parallelism of the fan shaft and the motor shaft.
Motor: The motor shall match with the fan load, and B3 installation structure shall be adopted. The protection grade of the motor shall be IP54, while insulation class F and temperature rise B. The motor bearing shall be self-lubricating ball bearing. And TEFC, 2-SPD, EXP, VFD, 60Hz and other correct motor types must be selected according to the specific working conditions.

Explosion-proof Structure (Only for explosion-proof type)
Fan shall conform to Spark C explosion-proof structure according to AMCA99 Standard. The inlet shall mount copper ring and the motor shall adopt explosion-proof type. The whole fan should own CNEX certification and the manufacturer must own the production license for anti-explosion electric products.

Options
Relevant accessories shall be provided according to the specific requirements for each set of equipment, such as air volume control damper, gravity-held air back draft damper , fireproof regulating damper, fire damper, Stainless steel blades , Stainless steel fasteners, etc.

Nameplate
Permanently fixed aluminum nameplate shall be fixed on fan body clearly display fan mark, product model and serial number (i.e.: unique ID for each fan), so that the customer can use this number to find out the parts used.

Acceptable Manufacturers
Qualified suppliers shall have an AAA credit rating. Providing INFINAIR or similar products, with their design based on YFWMF models of INFINAIR.

Online Message